Diesel Generator Set Data Set Type:XG-2200GF Standby Power:2200KW/2750KVA Prime Power:2000KW/2500KVA Rated Current:3600(A) Rated Frequency:50(Hz) Start-up time:5~6(s) Power Factor:0.8(Lag) Rated Voltage:400/230(V) Standard Features Engine:Cummins QSK60-G13 Radiator 50°C max Fans are driven by belt, with safety guard 24V charge alternator Dry type air filter, fuel filter, oil filter Alternator: single bearing alternator IP23, insulation class H/H Main line circuit breaker Standard control panel Absorber muffler User manual Diesel Engine Data Manufacturer:Cummins Model:QSK60-G13 Standby Power:2145KW Rated Speed:1500(r/min) Cycle:4 stroke Cylinder Arrangement:6 in line Displacement:60.2L Bore and Stroke:159*190(mm) Compression Ratio:14.5:1 Governor Type:Electronic Start battery voltage:24V DC Air Intake System Air Intake System:Turbo, Water/Air Cooling Max Intake Restriction:6.35kPa Burning Capacity:2050L/s Air Flow:29600L/s Exhaust System Exhaust Gas Flow:5020L/s Exhaust Temperature:480°C Max Back Pressure:5.1kPa Fuel System Fuel System:HPI PT type fuel pump 100%( Prime Power) Load:193g/kwh 50%( Prime Power) Load:210g/kwh Oil System Total Oil Capacity:280L Oil Consumption:≤4g/kwh Engine Oil Tank Capacity:250L Oil Pressure at Rated RPM:345-483kPa Cooling System Cooling Way:Water-cooled Total Coolant Capacity: 535L Thermostat:82-93°C Max Water Temperature:104°C Alternator Data Manufacturer:STAMFORD/SIEMENS/MARATHON/ENGGA Excitation Mode:Brushless and self- exciting Number of phase and Access Act: 3-phase 4-wire Connecting Type:“Y” type connecting Alternator Capacity:2750KVA Alternator Efficiencies:95% Overload:(PRP)110% load can run 1h Protection Level:IP22-IP23 Insulation Class, Temperature Rise:H/H Telephone Influence Factor (TIF):<50 THF:<2% Voltage Regulation, Steady State:≤±1% Air Cooling Flow:2.69m3/s Altitude:≤1000m Genset Electrical Performance Voltage Regulation:≥±5% Voltage Regulation, Stead State:≤±1% Sudden Voltage Warp (100% Sudden Reduce):≤+25% Sudden Voltage Warp (Sudden Increase):≤-20% Voltage Stable Time (100% Sudden Reduce):≤6S Voltage Stable Time (Sudden Increase):≤6S Frequency Regulation, Stead State:≤5% Frequency Waving:≤1.5% Sudden Frequency Warp (100% SuddenReduce):≤+12% Sudden Frequency Warp (Sudden Increase):≤-10% FrequencyRecoveryTime(100%SuddenReduce):≤5S FrequencyRecoveryTime(Sudden Increase): ≤5S
View as :

(13 - 14 out of 14)

  • Cummins 24kw Diesel Generator

    Cummins 24kw Diesel Generator

    • Place of origin : China
    • Min. Order : 1 set
    Diesel Generator Set Data Set Type:XG-24GF Standby Power:24KW/30KVA Prime Power:22KW/27KVA Rated Current:39(A) Rated Frequency:50(Hz) Start-up time:5~6(s) Power Factor:0.8(Lag) Rated Voltage:400/230(V) Standard Features Engine:DCEC Cummins 4B3.9-G2 Radiator 50℃ max Fans are driven by belt, with safety guard 24V charge alternator Dry type air filter, fuel filter, oil...
    [ Related Keywords : diesel generator, cummins, generator ]
  • Volvo 600KW Diesel Generator

    Volvo 600KW Diesel Generator

    • Place of origin : China
    Diesel Generator Set Data Set Type:XG-600GF Standby Output:600KW/750KVA Prime Output:545KW/682KVA Rated Current:982(A) Rated Frequency:50(Hz) Start-up time:5~6(s) Power Factor:0.8(Lag) Rated Voltage:400/230(V) Standard Features Engine:VOLVO TWD1643GE Radiator 50℃ max Fans are driven by belt, with safety guard 24V charge alternator Dry type air filter, fuel filter, oil...